Total Inspections
3
3 completed
Open NCRs
1
1 open, 0 under review
Open Punch Items
2
Class A & B
Completion Rate
100%
inspections completed
Recent Inspections
InspectionComponent PartDateProgressStatus
XYZ-INS-003BRACKET LEG2026-06-06
100%
COMPLETED
XYZ-INS-002MAIN FRAME WELD2026-06-05
100%
COMPLETED
XYZ-INS-001FOUNDATION GRID C2026-06-01
100%
COMPLETED
Open NCRs
Abc123-NCR-001
Check steel plate storage location
MINOROPENDue: 2026-06-13
Upcoming Punch Items
PUNCH-001A Class
Touch up paint on bracket leg bottom surface
Due: 2026-06-20  ·  Coating
PUNCH-002B Class
Install missing identification labels on all components
Due: 2026-06-25  ·  Documentation
Safety Observations
🚨
Workers not wearing safety glasses in grinding areaHIGH
📍 Area B, Bay 3  ·  2026-06-05  ·  OBS-001
⚠️
Missing barrier tape around excavation zoneMEDIUM
📍 Grid D Foundation  ·  2026-06-06  ·  OBS-002
Inspection Status
Draft — 0
In Progress — 0
Completed — 3
All Inspections 3 records
Inspection IDComponent PartTemplateDateInspectorProgressStatus
XYZ-INS-003BRACKET LEGStructural ITP2026-06-06J. Wang
5/5
COMPLETED
XYZ-INS-002MAIN FRAME WELDWeld Visual ITP2026-06-05J. Wang
6/6
COMPLETED
XYZ-INS-001FOUNDATION GRID CCivil ITP2026-06-01J. Wang
4/4
COMPLETED
Basic Information
Select Template
Inspection ID
XYZ-INS-004
Component Part
UPPER BRACKET
Date
2026-06-07
Status
IN PROGRESS
Structural Steel ITP — Checklist
0 / 5
#
Inspection Item
Acceptance Criteria
Result
Remark
01
Dimensional Check (length / width / thickness)
Per drawing ±2mm
02
Weld Visual Inspection (no cracks / porosity)
AWS D1.1 Section 6
03
Surface Treatment (blasting grade)
Sa 2.5 min
04
Bolt Torque Check
Per spec TQ-003
05
Material Certification Review
Mill cert. on file
All
Open
Under Review
Closed
NCR No.DescriptionInspectionSeverityRaised ByDue DateStatus
Abc123-NCR-001Check steel plate storage locationXYZ-INS-002MINORJ. Wang2026-06-13OPEN
OPEN
Abc123-NCR-001
Raised 2026-06-01  ·  Due 2026-06-13
Description
Steel plate stored without weatherproof covering in outdoor area — does not comply with ITP Section 4.2 storage requirements.
Non-Conformance Category
Storage & Handling
Action Required
Apply protective covering and submit photo evidence of corrective action. Re-inspection required prior to resuming fabrication.
Related Inspection
Details
Severity
MINOR
Raised By
J. Wang (FCE)
Assigned To
XYZ QC Team
Due Date
2026-06-13
Activity Log
NCR Raised
2026-06-01 · J. Wang
Notification Sent
2026-06-01 · System
Punch List 2 items
Punch No.CategoryDescriptionInspectionClassDue DateStatus
PUNCH-001CoatingTouch up paint on bracket leg bottom surfaceXYZ-INS-003A Class2026-06-20OUTSTANDING
PUNCH-002DocumentationInstall missing identification labels on all componentsXYZ-INS-003B Class2026-06-25OUTSTANDING
Summary
2
Outstanding
0
In Review
0
Cleared
1
High
1
Medium
0
Low
🚨
Workers not wearing safety glasses in grinding area
HIGH OPEN
3 workers operating angle grinders without eye protection. Immediate correction required — OHSAS 18001 Section 8.1.
📍 Area B, Bay 3  📅 2026-06-05  👤 J. Wang  OBS-001
⚠️
Missing barrier tape around excavation zone
MEDIUM OPEN
Excavation near Foundation Grid D lacks required 1.2m barrier tape and safety signage. Fall hazard identified.
📍 Grid D, Foundation Zone  📅 2026-06-06  👤 J. Wang  OBS-002
Project Documents 4 files
File Name
Type
Uploaded
Size
Actions
📋
XYZ-ITP-STR-001.pdf
Structural Steel Inspection & Test Plan
ITP
2026-05-15
2.4 MB
📄
FCE-PROC-WEL-001.pdf
Welding Inspection Procedure
Procedure
2026-05-10
1.1 MB
📐
XYZ-DRW-BRACKET-A3.pdf
Bracket Leg Assembly Drawing (Rev.2)
Drawing
2026-06-01
5.8 MB
📜
Material-Certificate-Q235B.pdf
Mill Test Certificate — Q235B Steel Plate
Certificate
2026-06-03
892 KB
THE ProQ™ ADVANTAGE
Real-Time Quality Control.
No Information Gap.
While your inspector is still on site — your client already knows the result.
No waiting. No surprises. No back-and-forth emails at handover.
INSPECTOR · ON SITE
Marks checklist in real time
Attaches photos and remarks
Logs NCRs and safety observations
Live Sync
zero
delay
MANAGER / CLIENT · OFFICE
Sees results as they happen
Reviews NCRs and reports live
Makes decisions with real data
Zero Reporting Lag
Results go live the moment the inspector submits — no email delays, no version confusion
Catch Issues Early
React before a defect becomes a delay — when corrective action is still cheap and fast
One Source of Truth
Field, PM, and client see the same live data — no more conflicting versions at handover
Ready to close the gap?  [email protected]
📄 XYZ-INS-004_Inspection_Report.pdf
ProQ
Forward C&E
INSPECTION REPORT
XYZ-INS-004 · Rev.0
Project Information
Project
XYZ — XYZ International
Component Part
UPPER BRACKET (Lot 03)
Inspection Date
2026-06-07
Inspector
J. Wang — Forward C&E
ITP Reference
XYZ-ITP-STR-001
Test Point
Hold (H)
Inspection Checklist Results
#Inspection ItemAcceptance CriteriaResult
1Dimensional Check (length/width/thickness)Per drawing ±2mmPASS
2Weld Visual Inspection (no cracks/porosity)AWS D1.1 Section 6FAIL *
3Surface Treatment (blasting grade)Sa 2.5 minPASS
4Bolt Torque CheckPer spec TQ-003PASS
5Material Certification ReviewMill cert. on filePASS
* FAIL — NCR raised: Abc123-NCR-001
Site Photos
IMG-001 · Steel Plate Visual · PASS
IMG-002 · Coating Film Inspection · PASS
IMG-003 · Weld Visual Inspection · ⚠ NCR RAISED
Summary & Conclusion
4 of 5 items PASS. Item 2 (Weld Visual) failed — surface porosity observed at weld seam W-03. NCR raised accordingly. Re-inspection required upon completion of corrective action.
Inspector Signature
J. Wang — Forward C&E
Date: 2026-06-07
Generated by ProQ™ · Forward Consulting & EngineeringPage 1 of 1 · 2026-06-07 14:30 CST